Nitrous Oxide Plants
We are one of the leading manufacturer and exporter of nitrous oxide plants. Our
Nitrous Oxide plant are very safe and economical plants with an efficient Generation system which reduces power consumption and adds on to safety. A storage battery assembly for separation of Nitrogen is another safety feature with the Universal plant. The gas manufactured conforms to Indian Pharmacopeias, US & European standards and is stored in liquid state which can be directly filled into cylinder.
| Chemical formula |
N2O |
| Molecular weight |
44.0128 |
| Specific volume at 15°C and 1 atm |
0.533m3/kg |
| Specific gravity (air=1) |
1.5297 |
| Density at 15°C and 1 atm |
1.877kg/m3 |
| Specific heat at 15°C and 1 atm |
0.866kj/kg (°C) |
Production Process
Nitrous Oxide is produced by heating Ammonium Nitrate to a temperature of 250 Deg.c. Ammonium Nitrate is decomposed in the process to give a mixture of Nitrous Oxide & super heated steam. At the same time impurities are produced including Ammonium Nitrate fumes, Nitrogen & other oxides of Nitrogen. The steam & impurities are removed by scrubbing with water, caustic soda and sulfuric acid in
sequence Nitrogen present in traces is removed by bleeding from the top of storage vessels where Nitrous Oxide is stored, after compression by a compressor. Capacities 8 - 24 cum/hr.
Salient Features if our Nitrous Oxide Plants
• Product purity meets world standards.
• Special safety features incorporated in the plant.
• Stainless Steel Construction.
• Decomposer and Melter separately mounted and controlled.
• Online moisture meter installed
• Complete laboratory equipment for testing of gas is provided with plant as stand ardaccessory.
• Double drier provided.
• Skid mounted, modular design occupies less space.
Cylinder Testing Station
A cylinder testing station (optional) can be provided to test cylinders. Similarly, a vacuum pump can be also provided to evacuate the cylinders received from customers which might be containing some left over impure nitrous oxide. A small laboratory is a must to maintain complete analysis of batch produced in the plant. The plant is automatic and required only 2 persons to operate per shift
besides a chemist.
Scope of Supply
GAS GENERATING
Consisting of Aluminium Heating and SYSTEM De composition Pots, Scrubbers for Water, Caustic Soda and Acid Circulating Pumps.
|
|
|
Alluminium Heating &
desomposition pot |
|
Caustic Soda and Acid Tank |
GAS HOLDER
Rubber Type Ballon Gas Holder of 8 Cu.m/hr capacity
GAS COMPRESSOR
(VERTICAL TYPE)
Two Stage, Water Lubricated Gas Compressor with Motor, Starter and
Purge Bottle to suit 8 Cu.m/hr capacity Plant.
|
| Gas driers with regenerating system |
GAS DRIERS
Containing Alumina Balls and with regenerating system such as Blower,
Heater etc. for regeneration in –situ
STORAGE VESSEL
100-200 Litres water capacity to store Liquid Nitrous Oxide with a proper venting arrangement to remove Nitrogen.
LABORATORY EQUIPMENTS
Consisting of:
Weighing Scale (Lab Model)
Water System
Gas Meter
All glass equipment for testing Nitrous Oxide as per I.P.
Glass equipment and flow meters for testing the impurities
General glass laboratory equipment and laboratory chemicals
WEIGHING SCALE
0-200 Kgs. Dial Scale
WATER SOFTENER PLANT
COOLING TOWER
SINGLE CYLINDER FILLING SYSTEM